Eutech Ph 510 Manual

Posted on

Growing Ideas Growing Products Two families of benchtop meters with BIGGER displays and more! Eutech 2700 Series Intuitive with advanced set-up options for user-customization, the Eutech 2700 series utech comes with a large, one-glance-tells-all screen that displays readings, electrode status, calibration points, date and time all at once! Ion 2700 measures pH, Ion, ORP and Temperature Page 28 pH 2700 measures pH, ORP, Temperature Page 29 CON 2700 measures Conductivity, Resistivity, Total Dissolved Solids, Salinity and Temperature Page 48 DO 2700 measures Dissolved Oxygen (in. PH Meter Quick Guide Conductivity Meter Quick Guide Total Dissolved Solids Meter Quick Guide Salinity Meter Quick Guide Dissolved Oxygen Meter Quick Guide Multi-Parameter Meter Quick Guide Colorimeter Quick Guide & Feature Icons 34 About Conductivity/TDS/ Salinity Measurement 36 ECTestr 11+; 11 & TDSTestr® 11+; 11 37 SaltTestr® 11 38 EcoTestr EC High/Low; TDS High/Low; Salt 39 Pocket Testers Specs 40 Pocket Testers Ordering Info 41 CyberScan COND 610; 600 42 CyberScan CON 400 43 CyberScan CON 110; 11 44 COND 6+; TDS 6+ 45 Salt 6+ 46 Handheld Meters Specs 47 Handheld Meters Ordering Info 48.

Selection Guide Meter Selection Guide pH Meter Quick Guide Meter Selection Guide pH Meter Quick Guide Models Cal. PH Buffer Sets Points Temperature Housing Page Communication Display Rating No. Pocket Testers PCSTestr 35 PCTestr 35 PTTestr 35 pHTestr 30 pHTestr 20 pHTestr 10 EcoTestr pH 2 pHTestr 10BNC pH Spear Handheld Meters CyberScan PCD 650 pH/Conductivity/TDS/ Salinity/ºC/ºF pH/Conductivity/ºC/ºF pH/TDS/ºC/ºF pH/ºC/ºF pH pH pH pH/ºC/ºF pH/ºC/ºF pH/ORP/Ion/ Conductivity/TDS/ Salinity/Resistivity/ Dissolved Oxygen/ºC/ºF pH/ORP/Ion/ Conductivity/TDS/ Salinity/Resistivity/ºC/ºF. Conductivity Meter Quick Guide Models Conductivity Range Temperature Housing Page Communication Display Rating No. Pocket Testers PCSTestr 35 PCTestr 35 ECTestr 11+ ECTestr 11. To 200.0 μS 200 to 2000 μS 2.00 to 20.00 mS.

Eutech ph 510 manual download

To 2000 μS pH/Conductivity/ºC/ºF 2.00 to 20.00 mS. To 200.0 μS Conductivity/ºC/ºF.

To 2000 μS Conductivity/ºC/ºF. To 20.00 mS pH/Conductivity/TDS/ Salinity/ºC/ºF EcoTestr EC Low Handheld Meters. To 2.000 μS pH/ORP/Ion/ 2.000 to 300.0 μS Conductivity/TDS/ 300.0 μS to 4.000 mS CyberScan PCD 650 Salinity/Resistivity/ 4.000 to 40.00 mS. Selection Guide Meter Selection Guide Total Dissolved Solids Meter Quick Guide Total Dissolved Solids Meter Quick Guide Models Temperature Housing Page Communication Display Rating No. ±1% full scale (±2% above 5 ppt) ±1% full scale ±1% full scale ±1% full scale ±1% full scale Handheld Meters.

To 2.000 ppm pH/ORP/Ion/ 2.000 to 300.0 ppm Conductivity/TDS/ 300.0 ppm to 4.000 ppt CyberScan PCD 650 Salinity/Resistivity/ 4.000 to 40.00 ppt Dissolved Oxygen/ºC/ºF 40.00 to 500.0 ppt. To 2.000 ppm pH/ORP/Ion/ 2.000 to 300.0 ppm CyberScan PC 650 Conductivity/TDS/ 300.0 ppm to 4.000 ppt. Salinity Meter Quick Guide Models Salinity Range Temperature Housing Page Communication Display Rating No. Pocket Testers PCSTestr 35 pH/Conductivity/TDS/ Salinity/ºC/ºF EcoTestr Salt ±1% full scale ±1% full scale (±2% above 5 ppt) Handheld Meters. To 0.770 ppm pH/ORP/Ion/ 0.770 to 143.3 ppm Conductivity/TDS/ 143.3 ppm to 2.138 ppt CyberScan PCD 650 Salinity/Resistivity/ 2.183 to 23.64 ppt Dissolved Oxygen/ºC/ºF 23.64 to 80.00 ppt.

Eutech Ph 700 Manual

To 0.770 ppm pH/ORP/Ion/ 0.770 to 143.3 ppm CyberScan PC 650 Conductivity/TDS/ 143.3 ppm to 2.138 ppt Salinity/Resistivity/ºC/ºF 2.183 to 23.64 ppt 23.64. Selection Guide Meter Selection Guide DO Meter Quick Guide Dissolved Oxygen Meter Quick Guide Models Barometric / Salinity Housing Page Communication Compensation Rating No. ±1.5% full scale ±1.5% full scale ±1.5% full scale Handheld Meters CyberScan PCD 650 CyberScan PD 650 CyberScan CD 650 CyberScan DO 600 CyberScan DO 300 CyberScan DO 110 DO 6+ pH/ORP/Ion/ 0 to 600%, Conductivity/TDS/ 0.00 to 90.00 mg/L Salinity/Resistivity/ or ppm Dissolved Oxygen/ºC/ºF 0 to 600%, pH/ORP/Ion/Dissolved 0.00 to 90.00 mg/L Oxygen/ºC/ºF or ppm Conductivity/TDS/ 0 to 600%, Salinity/Resistivity/ 0.00 to. Multi-Parameter Meter Quick Guide Models Temperature Housing Page Communication Display Rating No. Pocket Testers Conductivity TDS PCSTestr 35 Salinity Temperature pH PCTestr 35 1 (manual ± 1% full scale.

above 1.00 ppt) 0.5 ºC; 0.9 ºF ±0.01 pH ± 1% full scale 0.5 ºC; 0.9 ºF ±0.01 pH – 5 auto 2 auto 2 manual – 5 auto. To 2.000 μS; 2.000 to 300.0 μS; 300.0 μS to 4.000 mS; Conductivity 4.000 to 40.00 mS; 40.00 to 500.0 mS. To 2.000 ppm; 2.000 to 300.0 ppm; TDS 300.0 ppm to 4.000 ppt; 4.000 to 40.00 ppt; 40.00 to 500.0 ppt.

To 0.770 ppm; 0.770 to 143.3 ppm; Salinity 143.3. Selection Guide Meter Selection Guide Multi-Parameter Meter Quick Guide Multi-Parameter Meter Quick Guide Continued from page 9 ±0.002 pH ±0.2 mV 0.5% full scale (monovalent) 1% full scale (divalent) Temperature Housing Page Communication Display Rating No. Handheld Meters CyberScan PD 650 0.00 to 90.00 mg/L or ppm 0 to 600.0% -10.0 to 110.0 ºC; Temperature 14.0 to 230.0 ºF. To 2.000 μS 2.000 to 300.0 μS Conductivity 300.0 μS to 4.000 mS 4.000 to 40.00 mS 40.00 to 500.0 mS. To 2.000 ppm 2.000 to 300.0 ppm TDS 300.0 ppm to 4.000 ppt 4.000 to 40.00 ppt 40.00 to 500.0 ppt. Multi-Parameter Meter Quick Guide Continued from page 10 Conductivity TDS Salinity Resistivity ±0.002 pH 0.1 mV 0.5% full scale (monovalent) 1% full scale (divalent) ±1% full scale ±1% full scale ±1% full scale ±1% full scale ±0.3 ºC; ±0.5 ºF ±0.01 pH + 1 LSD ±0.2 mV (±199.9 mV) ±2 mV (beyond) ±1% full scale Temperature Housing Page Communication Display Rating No.

Bench Meters Selection Guide Meter Selection Guide Multi-Parameter Meter Quick Guide All Thermo Scientific Eutech Instruments catalogs and technical brochures.

Instruction Manual PC 700 pH/mV/Conductivity/ºC/ºF Bench MeterTechnology Made Easy.Part of Thermo Fisher Scientific68X541704 Rev 4 Apr 2013TABLE OF CONTENTS 1. GETTING STARTED.

2 2.1 2.2 2.3Keypad Functions. 2 LCD Annunciators. 3 Meter Connections. CONDUCTIVITY ELECTRODE.

PH AND MV CALIBRATION. 4 4.1 4.2pH Calibration. 4 Millivolt (mV) Offset Adjustment. CONDUCTIVITY AND TDS CALIBRATION.

6 5.1 5.2 5.3 5.4 5.5 5.6Automatic or Manual Calibration. 6 Single or Multi-Point Calibration. 7 General Calibration Tips.

8 Automatic Conductivity Calibration Procedure. 8 Manual Conductivity & TDS Calibration Procedure. 9 Temperature Calibration. CONDUCTIVITY AND TDS MEASUREMENT. 10 6.1 6.2Taking Measurements. 10 Automatic and Manual Ranging.

HOLD FUNCTION. STORING AND RECALLING DATA.

SETUP FUNCTIONS. 12 9.1 9.2 9.3 9.4 9.5 9.61.0 CAL (Calibration). 12 2.0 ELE (Electrode Information). 12 3.0 ConF (Configuration).

13 3.1 rdY (Ready / Stability Indicator). 13 3.2 ºC ºF (Celsius or Fahrenheit). 13 3.3 buFF (pH Buffers & Calibration Points)—pH only. 139.7 9.8 9.9 9.10 9.11 9.12 9.13 9.14 9.153.3 AtC (Auto Temp Compensation)—Con & TDS only. 14 3.4 tdS (TDS factor)—Con & TDS only. 14 3.5 t.CO (Temperature Coefficient)—Con & TDS only.

14 3.6 t.nr (Normalization Temperature in ºC)—Con & TDS only 15 3.7 ACAL (Auto Conductivity Calibration)—Con & TDS only. 15 3.8 SPC (Single Point Calibration)—Con & TDS only. 15 3.8 CELL (Nominal Cell Constant)—Con & TDS only. 15 4.0 rSt (Reset).

16 5.0 CLr (Clear Memory). CALCULATING TDS CONVERSION FACTOR. CALCULATING TEMPERATURE COEFFICIENTS. REPLACEMENTS AND ACCESSORIES. TROUBLESHOOTING GUIDE. RETURN OF ITEMS.

INTRODUCTIONThank you for purchasing our PC 700 series benchtop meter. This microprocessor-based meter is economical and simple to use. The design incorporates a large LCD for clear viewing, yet offers a small footprint to conserve space. The PC 700 measures pH, mV (ORP), conductivity, or TDS simultaneously with temperature (ºC or ºF). Each meter includes a convenient slide-out card for quick reference.

Also included is an electrode arm and metal bracket which can be easily attached to the left or right side of the meter according to your preference. The PC 700 benchtop meter replaces our popular pH/CON 510 series meter that was introduced in 2000. We take great pride in every instrument we manufacture and hope this one serves you well.12. GETTING STARTED2.1 Keypad Functions Powers the meter on and off. Upon power on, the meter automatically begins in the mode that was last used. Calibration and memory values are retained even if meter is unplugged. Toggle between available measurement modes— pH/Temp, mV/Temp, Conductivity/Temp, or TDS/Temp.

Also used to switch to Temperature calibration during pH, mV, Conductivity or TDS calibration modes. Press and hold for 5 seconds to enter SETUP mode. Toggles between measurement and calibration modes. In SETUP mode, returns user to the measurement mode. Confirms calibration values in CAL mode.

Confirms selections in SETUP mode. Changes Con/TDS range and resolution in MEAS mode. View recalled values in memory mode. MI (Memory Insert) stores values into memory.

Eutech Ph 510 Manual Download

 Increase value. Scroll up in SETUP & CAL modes. MR (Memory Recall) recalls values from memory  Decrease value.

Eutech Ph 510 Manual Instructions

Eutech Ph 510 Manual

Scroll down in SETUP & CAL modes. Freezes measured reading. Press again to resume live reading.22.2 LCD Annunciators2.3 Meter ConnectionsDC CON/ TEMP pHPower supply 8-pin DIN connection for 2-cell Con/TDS/Temp electrode BNC connection for pH, or ORP (Redox) electrode33. CONDUCTIVITY ELECTRODEThe PC 700 includes an electrode with a nominal cell constant of k = 1.0, built-in temperature sensor, and 1 meter cable. The Ultem body housing has good chemical resistant properties. The electrode design offers fast temperature response and reduces air entrapment, ensuring accurate, repeatable, and stable readings.

The wetted materials of the probe include:.Polyetherimide (Ultem) – protective probe guard.Polybutylterphalate (Valox) – sensor housing.Stainless Steel (SS 304) – 2 bandsThe protective probe guard can be removed temporarily for cleaning however it must be re-attached during measurement and calibration. Erroneous results will occur while the probe guard is removed. Always immerse the probe beyond upper steel band for best results. Use the fill line on the outside of the probe guard for reference. Zakazana retorika pdf.

PH AND MV CALIBRATION4.1 pH Calibration For best results, periodic calibration with known accurate standards is recommended. Calibrate with standards that bracket your intended measuring range while including a neutral standard (pH 7.00 or 6.86). For example, if you expect to measure samples from pH 6.2 to pH 9.5, calibration with 4.01, 7.00, and 10.01 will work well. The PC 700 meter can be calibrated with up to 5 buffers.

The non-volatile memory retains all calibration values upon meter shut down.4The following calibration standards are automatically recognized; USA buffer group1.68, 4.01, 7.00, 10.01, 12.45NIST buffer group1.68, 4.01, 6.86, 9.18, 12.45See Section 9.6 to change the buffer group 1) Pressas needed to select pH.2) Dip the pH and ATC electrodes into pH buffer and press. The secondary display will lock on the appropriate buffer value. Provide stirring for best results. When the READY indicator appears, press to accept. The primary reading will flash briefly before the secondary display begins scrolling the remaining available buffers.

3) Rinse the pH and ATC electrodes then dip into the next pH buffer. The secondary display will lock on the appropriate buffer value. When the READY indicator appears, press to accept. The primary reading will flash briefly then display the percent efficiency (slope) before the secondary display begins scrolling the remaining available buffers. 4) To calibrate another buffer repeat step 3) or press to return to the measurement mode.

Note: The meter will automatically return to measurement mode upon successful completion of the number of specified calibration points. To specify a different number of pH calibration points see Section 9.6. TIPS: A single point (offset) calibration is only allowed with pH 7.00 or pH 6.86 buffers.

When the first calibration value is accepted during a new calibration, all prior calibration values are erased. Press mode.at any time to abort calibration and return to measurement54.2 Millivolt (mV) Offset Adjustment Oxidization Reduction Potential (ORP or Redox) is not a precise measurement, but is useful as a relative indicator. As such, mV offset adjustment is not meant to enhance accuracy, but rather to make readings comparable to a reference. Commercial ORP solutions are often used as a check standard in which a meter/electrode system are verified to be close to a given value, instead of being used as a calibration standard in which adjustments are made in an attempt to match the ORP value.

Manual

1) Connect an ORP electrode and press (or R.mV).as needed to select mV2) Dip the ORP electrode into a solution with a known mV value (i.e. Zobel, Light’s, quinhydrone, or iodidetriiodide) and stir.

When the reading is stable. The primary display shows 3) Press the relative millivolt value (R.mV) while the secondary display shows the factory default mV value.

4) Adjust the R.mV value usingor. Pressto accept orto cancel. The meter allows an adjustable maximum value of ± 150 mV from the factory default mV value. Note: When an offset has been stored successfully, R.mV replaces mV. CONDUCTIVITY AND TDS CALIBRATION5.1 Automatic or Manual Calibration The PC 700 is capable of automatic or manual calibration for conductivity, and manual calibration for TDS.

In the automatic calibration mode, the meter will automatically select one of (4) conductivity calibration standard values depending on the range and normalization temperature being used (TABLE 1).6If you only use calibration standards that are listed in TABLE 1, automatic calibration is recommended. If you intend to calibrate with one or more standards that are not listed in TABLE 1, the PC 700 must be set for manual calibration instead. The factory default is automatic conductivity calibration.

See Section 9.11 to change this setting.